{"id":1734,"date":"2016-11-24T12:28:16","date_gmt":"2016-11-24T12:28:16","guid":{"rendered":"http:\/\/healvita.esy.es\/?page_id=1734"},"modified":"2018-03-13T11:24:20","modified_gmt":"2018-03-13T10:24:20","slug":"early-warning-environmental-radiation-monitoring-networks","status":"publish","type":"page","link":"https:\/\/www.healvitagroup.com\/index.php\/nuclear\/early-warning-environmental-radiation-monitoring-networks\/","title":{"rendered":"Early Warning Environmental Radiation Monitoring Networks"},"content":{"rendered":"<p id=\"ZAsZZEm\"><img loading=\"lazy\" class=\"wp-image-2198 alignnone\" src=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/\/wp-content\/uploads\/2016\/12\/img_5849272348c46.png?resize=99%2C96\" alt=\"\" width=\"99\" height=\"96\" data-recalc-dims=\"1\" \/><img loading=\"lazy\" width=\"389\" height=\"141\" class=\"size-full wp-image-2197 alignnone\" src=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/\/wp-content\/uploads\/2016\/12\/img_5849271325e0d.png?resize=389%2C141\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2016\/12\/img_5849271325e0d.png?w=389&amp;ssl=1 389w, https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2016\/12\/img_5849271325e0d.png?resize=300%2C109&amp;ssl=1 300w\" sizes=\"(max-width: 389px) 100vw, 389px\" data-recalc-dims=\"1\" \/><img loading=\"lazy\" class=\"wp-image-2199 alignnone\" src=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/\/wp-content\/uploads\/2016\/12\/img_58492733aa02c.png?resize=103%2C100\" alt=\"\" width=\"103\" height=\"100\" srcset=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2016\/12\/img_58492733aa02c.png?w=214&amp;ssl=1 214w, https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2016\/12\/img_58492733aa02c.png?resize=50%2C50&amp;ssl=1 50w\" sizes=\"(max-width: 103px) 100vw, 103px\" data-recalc-dims=\"1\" \/><\/p>\n<p>HEALVITA is specialised in providing radiation early warning networks, gamma dose rate and alpha-, beta-,\u00a0gamma- aerosol activity at the environment.<\/p>\n<p id=\"pdmbAEK\"><img loading=\"lazy\" width=\"439\" height=\"517\" class=\"alignnone size-full wp-image-3015 \" src=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a04f51d31.png?resize=439%2C517\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a04f51d31.png?w=439&amp;ssl=1 439w, https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a04f51d31.png?resize=255%2C300&amp;ssl=1 255w\" sizes=\"(max-width: 439px) 100vw, 439px\" data-recalc-dims=\"1\" \/><\/p>\n<p>System comprises these main parts:<br \/>\n\u00b7 3&#8243; NaI detector with associated electronics (multi channel analyzer \u2013 MCA)<br \/>\n\u00b7 Aluminum protection case for detector and MCA with connector<br \/>\n\u00b7 Cabinet with LiFePo battery (60Ah, 24V), power regulator, embedded industrial PC with GPRS modem<br \/>\n\u00b7 Mast (holder) for mounting cabinet, detector assembly and solar panel<br \/>\n\u00b7 Solar PV panel (1 piece), minimum 280 Wp<br \/>\n\u00b7 Cables<br \/>\n\u00b7 Software for embedded industrial PC<\/p>\n<p>Measured data will be transferred using GPRS modem to the central station (ENVINET server). Data will be accessible by thin web client application. System will provide selected nuclide activities according to the library with associated uncertainties (or MDAs) as well as ambient dose rate equivalent (in \u03bcSv.h-1) and raw spectrum (1024 or 2048 channels). Automatic spectrum stabilization is based on 1461 keV peak of K-40 nuclide.<\/p>\n<p><strong>Radiation Detection Mobile Laboratory<\/strong><\/p>\n<p><img loading=\"lazy\" class=\"alignnone\" src=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2016\/11\/car-1.jpg?resize=277%2C188\" width=\"277\" height=\"188\" data-recalc-dims=\"1\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>SCADA (Supervisory Control And Data Acquisition)<\/strong><\/p>\n<p>SCADA is a software package for an early radiation monitoring control center. The abbreviation \u201cSCADA\u201d (Supervisory Control And Data Acquisition) explains its features briefly in summary very well. SCADA acquires data from measuring stations and provides visualization as well as the control of the stations is possible.<\/p>\n<p>Data can be acquired from any measuring station. These mainly are: WEBDL (Data Logger for gamma probe), autonomous solar station, \u201cAerosol Measuring Station\u201d (AMS), as well as the new developed \u201cElectrostatic Universal Radiation Monitor\u201d (EURM). For information about these products please\u00a0contact our company.<\/p>\n<p id=\"LcreMEg\"><img loading=\"lazy\" width=\"860\" height=\"405\" class=\"alignnone size-full wp-image-3016 \" src=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a2791a6ab.png?resize=860%2C405\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a2791a6ab.png?w=860&amp;ssl=1 860w, https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a2791a6ab.png?resize=300%2C141&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a2791a6ab.png?resize=768%2C362&amp;ssl=1 768w\" sizes=\"(max-width: 860px) 100vw, 860px\" data-recalc-dims=\"1\" \/><\/p>\n<p>The SCADA system software package includes specific information management system for radiation environmental monitoring.\u00a0It\u00a0 is an efficient tool for data acquisition, evaluating and publishing of radiation monitoring data in the monitored area\/territory. Information system for environmental radiation monitoring network acquires the data from early warning or temporary emergency networks \u2013 continuous measurements \u2013 includes photon dose\u00a0equivalent rate and\/or spectra measured at points of network of early detection. Server based system that remotely monitors and controls the status, operation, data transmission, data storage, data\u00a0 handling, data analysis and display for all radiation monitoring systems within the Environmental\u00a0Radiation Monitoring Network.<\/p>\n<p id=\"komfDWh\"><img loading=\"lazy\" width=\"510\" height=\"556\" class=\"size-full wp-image-3017 alignleft\" src=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a29213d1c.png?resize=510%2C556\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a29213d1c.png?w=510&amp;ssl=1 510w, https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a29213d1c.png?resize=275%2C300&amp;ssl=1 275w\" sizes=\"(max-width: 510px) 100vw, 510px\" data-recalc-dims=\"1\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Online Real Time Sea Water and Drinking Water Monitoring System<\/strong><\/p>\n<p id=\"KLXnOjK\"><img loading=\"lazy\" width=\"213\" height=\"297\" class=\"alignnone size-full wp-image-3022 \" src=\"https:\/\/i0.wp.com\/www.healvitagroup.com\/wp-content\/uploads\/2018\/03\/img_5aa7a5572332f.png?resize=213%2C297\" alt=\"\" data-recalc-dims=\"1\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>HEALVITA is specialised in providing radiation early warning networks, gamma dose rate and alpha-, beta-,\u00a0gamma- aerosol activity at the environment. System comprises these main parts: \u00b7 3&#8243; NaI detector with associated electronics (multi channel analyzer \u2013 MCA) \u00b7 Aluminum protection case for detector and MCA with connector \u00b7 Cabinet with LiFePo battery (60Ah, 24V), power<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1731,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.healvitagroup.com\/index.php\/wp-json\/wp\/v2\/pages\/1734"}],"collection":[{"href":"https:\/\/www.healvitagroup.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.healvitagroup.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.healvitagroup.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.healvitagroup.com\/index.php\/wp-json\/wp\/v2\/comments?post=1734"}],"version-history":[{"count":22,"href":"https:\/\/www.healvitagroup.com\/index.php\/wp-json\/wp\/v2\/pages\/1734\/revisions"}],"predecessor-version":[{"id":3025,"href":"https:\/\/www.healvitagroup.com\/index.php\/wp-json\/wp\/v2\/pages\/1734\/revisions\/3025"}],"up":[{"embeddable":true,"href":"https:\/\/www.healvitagroup.com\/index.php\/wp-json\/wp\/v2\/pages\/1731"}],"wp:attachment":[{"href":"https:\/\/www.healvitagroup.com\/index.php\/wp-json\/wp\/v2\/media?parent=1734"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}